HI96714 Cyanide Portable Photometer
AL CHECK™
User calibration
Certified calibration and verification standards
BEPS (Battery Error Prevention System)
TIMER function
Auto shut-off
GLP Features
The HI 96714 meter measures the cyanide concentration in waters. The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same pos…
HI96729 Fluoride, Low Range, Portable Photometer
CAL CHECK™
User calibration
Certified calibration and verification standards
BEPS (Battery Error Prevention System)
TIMER function
Auto shut-off
GLP Features
The HI 96729 meter measures the fluoride (F–) content in the 0.00 to 2.00 mg/L (ppm) range, in drinking, surface and waste waters. The…
HI96700 Ammonia, Low Range, Portable Photometer
CAL CHECK™
User calibration
Certified calibration and verification standards
BEPS (Battery Error Prevention System)
TIMER function
Auto shut-off
GLP Features
The HI 96700 meter measures the ammonia-nitrogen (NH3-N) content in water samples.
These meters use an exclusive positive-locking system to ens…
Chlorine, Total Low Range, Portable Photometer
CAL CHECK™
User calibration
Certified calibration and verification standards
BEPS (Battery Error Prevention System)
TIMER function
Auto shut-off
GLP Features
The HI 96761 meter measures the traces of total chlorine (Cl2) content in drinking water samples.
This meter uses an exclusive positive-locking s…
玻璃量筒25mL/HI740220/Glass Cylinder Set
25 mL glass cylinder set of 2. Caps included
Order Information:
2 pcs
Glass cuvettes are constructed of precision glass, necessary for taking accurate measurements with photometers and turbidity meters. Care must be taken when handling. It is important that the cuvette is always clean and without scratches.
HI 731321 For use with HI 83 series photometers, and turbidimeters.
Order Information:
4 pcs (caps not included)
Glass Cuvette Set/玻璃比色皿/哈納比色皿
HI731331/hi731333/Hi731335
Glass cuvette for portable photometers, and turbidimeters.
Glass cuvettes are constructed of precision glass, necessary for taking accurate measurements with photometers and turbidity meters. Care must be taken when handling. It is important that the cuvette is always clean and without scratches.
Order Information:
4 pcs
HI731333/HI731331
Glass cuvette for portable photometers, and turbidimeters.
Glass cuvettes are constructed of precision glass, necessary for taking accurate measurements with photometers and turbidity meters. Care must be taken when handling. It is important that the cuvette is always clean and without scratches.
Order Information:
4 pcs
Cap Set for Glass Cuvettes
HI 731335N For use with HI 731331 glass cuvettes.
Order Information:
4 pcs.
Multiple ranges
Automatic calibration
Automatic Temperature Compensation
HOLD function
BEPS (Battery Error Prevention System)
Battery % on Startup
DiST® 7 is a handheld meter from HANNA that is designed for quick and easy EC, TDS and temperature measurements with high accuracy. This waterproof instrument displays EC or TDS and temperature in either °C o…
345 條記錄 25/35頁
首頁
上一頁
下一頁
尾頁